jagomart
digital resources
picture1_Radiographic Testing Pdf 91744 | Radiographic Testing (rt) En


 195x       Filetype PDF       File size 0.39 MB       Source: www.applus.com


File: Radiographic Testing Pdf 91744 | Radiographic Testing (rt) En
contact info applus com radiographic testing rt radiographic testing rt is one of the most fundamental volumetric testing methods performed in the industry radiography encompasses a wide range of techniques ...

icon picture PDF Filetype PDF | Posted on 16 Sep 2022 | 3 years ago
Partial capture of text on file.
                                     Contact: info@applus.com
       Radiographic Testing (RT)
       Radiographic testing (RT) is one of the most fundamental volumetric testing methods 
       performed in the industry. Radiography encompasses a wide range of techniques from 
       film usage to digital, with digital techniques ranging from computed (CR) and direct (DR) 
       to real-time radiography (RTR) and computed tomography (CT). All of these techniques 
       involve either X-ray or gamma radiation generated from a tube or from an isotope of 
       Iridium-192, Selenium-75 or Cobalt-60. RT has the ability to penetrate wide ranges of 
       material with varying densities to detect internal defects in weld quality; profile in-
       service systems to determine if corrosion or erosion is present; evaluate castings for 
       fabrication flaws or foreign objects; and detect damage in composites.
       THE Applus+ SOLUTION
       Applus+ is a world-leading authority in radiographic testing, a technique ideally suited to 
       the detection of imperfections in materials throughout industrial operations and 
       applications. Radiographic testing is used to meet the challenge of identifying issues 
       across production assets and equipment applications in the oil and gas industry. 
        
       Additionally, Applus+ leads the field in advanced technology with its own RandD 
       laboratories, worldwide resources and geographical coverage. We work closely with 
       industry leaders and subject experts.
        
       Applus+ has developed the Rayscan System, a real-time digital radiographic inspection 
       system capable of completing a full inspection of a production pipe in a single scan 
       rotation. This same technology has transcended into Rayscan Tankscan, the real-time 
       digital radiographic inspection system that can complete a full inspection of LNG storage-
       tank welds in a single scan, producing a high-quality image of each weld.
       Target customers
                                 Contact: info@applus.com
      Radiography has a number of applications within the industry. Whether it be 
      conventional film or digital, RT can be used to verify weld quality or to profile in-service 
      piping to determine the presence of corrosion under insulation (CUI), flow-accelerated 
      corrosion (FAC) or remaining wall thicknesses.
       
      RT has been employed in several industries and for a variety of inspection types, 
      including:
         Petrochemical
         Nuclear
         Fossil
         Chemical
         Military
         Aerospace
         Foundries
         New construction
         Post-construction
         Corrosion monitoring
         LNG fabrication
       
      Radiography is also a widely used volumetric-testing technique, and Applus+ is a time-
      tested provider of this service in the industry.
      Key customer benefits
      Advantages of using digital radiography:
         Direct results after scanning on site
         Large dynamic range
         Dose reduction (up to 90% in some cases)
         Smaller boundaries
         No use of chemicals or darkrooms
         Use of image-processing tools
         Digital archiving, reporting and transporting
         Significantly fewer re-shoots
         Digital images
         Increased probability of detection
       
      Advantages of Rayscan/Tankscan Real-Time Digital Radiography over conventional film 
      radiography:
         Cost efficient; no consumables
         Quick cycle-time
                                 Contact: info@applus.com
           High scan-speed
           No development time
           Direct interpretation and feedback
         Quality equal to/better than film
         Increased safety
           Reduced radiation required
           Collimated X-ray beam
           Shielded scanner design
         Environmentally friendly; no chemical waste management required
         High suitability for:
           Pipes with diameters of 5cm to 142cm (2” to 56”)
           Thin walls
           Austenitic materials
           Dissimilar welds
           CRA pipelines
           Root and hot-pass inspections
The words contained in this file might help you see if this file matches what you are looking for:

...Contact info applus com radiographic testing rt is one of the most fundamental volumetric methods performed in industry radiography encompasses a wide range techniques from film usage to digital with ranging computed cr and direct dr real time rtr tomography ct all these involve either x ray or gamma radiation generated tube an isotope iridium selenium cobalt has ability penetrate ranges material varying densities detect internal defects weld quality profile service systems determine if corrosion erosion present evaluate castings for fabrication flaws foreign objects damage composites solution world leading authority technique ideally suited detection imperfections materials throughout industrial operations applications used meet challenge identifying issues across production assets equipment oil gas additionally leads field advanced technology its own randd laboratories worldwide resources geographical coverage we work closely leaders subject experts developed rayscan system inspectio...

no reviews yet