177x Filetype PDF File size 2.52 MB Source: www.kcprofessional.co.in
* Kimtech Pure A5 Sterile Cleanroom Apparel Gowning Procedure Before Gowning Step 1 Step 3 Step 5 Step 6 (Pre-Entry) Don Hair Net and Shoe Apply mask and hood assuring Grasp the blue line. Gently unfold coverall utilizing blue Covers after removing all jewelry a snug fit. Located on the inside middle back. indicator line. Arms and legs are pre-drawn and cosmetics. and snapped in place. Garment is already folded inside-out and unzipped. Step 2 Step 4 (Gowning) Wash hands and gown first Open vacuumed-packed apparel. pair of sterile gloves. Sanitize gloves Tear at notched edge. Snaps allow gathered- after gowning each article if required. up arms and legs to expand during gowning. Begin Gowning Step 7 Step 8 Step 9 Step 10 Hold garment at waist. Put one leg in and Do the same with Insert one arm and point toe through the other leg. extend until snap opening until snap releases. releases. Step 11 Step 12 Final Step After A5 Sterile Cleanroom Do the same with Slip thumbs through Cross legs and Apparel is gowned the other arm. thumb loops. zip up coverall. • Add boot covers. • Complete gowning by adding goggles and a second pair of sterile gloves. * For more information, contact your local Kimberly-Clark Professional Sales Representative at 1-800-255-6401 or visit www.kimtech.com. ®/*Trademarks of Kimberly-Clark Worldwide, Inc. or its affiliates. Marques deposees de Kimberly-Clark Worldwide, Inc. ou de ses filiales. ©2014 KCWW. S44 P14-724 3/14