jagomart
digital resources
picture1_Industrial Pdf 195247 | Element21


 157x       Filetype PDF       File size 0.11 MB       Source: hunt-db.medisin.ntnu.no


File: Industrial Pdf 195247 | Element21
element series icp ms page 1 of 2 spectroscopy elemental analysis instruments equipment other spectroscopy elemental analysis instruments element series icp ms element series icp ms thermo scientific related applications ...

icon picture PDF Filetype PDF | Posted on 07 Feb 2023 | 2 years ago
Partial capture of text on file.
                             ELEMENT™ Series ICP-MS                                                                                                                                                                                                               Page 1 of 2
                                Spectroscopy & Elemental Analysis Instruments & Equipment › Other Spectroscopy & Elemental Analysis Instruments › ELEMENT™ Series ICP-MS
                                ELEMENT™ Series ICP-MS
                                                                                                                                                              Thermo Scientific™  Related applications: Industrial Mass Spectrometry
                                                                                                                                                             Choose from two high performance, double focusing magnetic sector field Thermo Scientific™ 
                                                                                                                                                             ELEMENT™ Series ICP-MS instruments that are optimized for ease-of-use, stability and 
                                                                                                                                                             productivity. The ELEMENT 2™ ICP-MS features powerful techniques that solve specific 
                                                                                                                                                             problems, combined with excellent sensitivity and signal-to-noise ratio. The Thermo Scientific 
                                                                                                                                                             ELEMENT XR™ ICP-MS extends the linear dynamic range of the ELEMENT 2 ICP-MS by an 
                                                                                                                                                             additional three orders of magnitude using a Faraday detector combined with the dual mode 
                                                                                                                                                             SEM detector.
                                                                                                                                                                                                                                            Contact us for support › 
                                  Catalog number                                                                          Product Size                                     Description                                       Price (NOK)
                                  IQLAAEGAAMFABWMAFC                                                                      -                                                ELEMENT 2                                         Request A Quote
                                     Full specifications  
                                  IQLAAEGAAMFABWMAFB                                                                      -                                                ELEMENT XR                                        Request A Quote
                                     Full specifications  
                                Description
                                ICP-MS is the most powerful technique for the quantification of trace elements. The most severe limitation of ICP-MS is 
                                polyatomic interference with elemental signals. High mass resolution is the gold standard for the elimination of these 
                                interferences, enabling accurate and reliable quantitative multi-element analyses at trace levels, even with minimal sample 
                                preparation.
                                Multi-elemental Analysis
                                   •  A multi-elemental detector with the speed to handle transient signals including HPLC, GC and laser ablation.
                                   •  Interference-free measurement across the periodic table covers matrix components (mg·L-1) to ultratrace element levels 
                                      (sub pg·L-1).
                                   •  Highest sensitivity ICP-MS (at low resolution).
                                Flexibility and Accessibility
                                   •  High mass resolution to access spectrally interfered isotopes and generate unambiguous elemental spectra.
                                   •  High precision isotope ratios on non-interfered or interfered isotopes.
                                   •  Hot and cold plasma conditions.
                                ELEMENT XR ICP-MS
                                Wide linear dynamic detection range is of immense importance in ICP-MS because it allows a wide range of concentrations to be 
                                analyzed in a single run.
                                Integrated Faraday Detector features:
                                   •  Sample times as low as 1ms.
                                   •  No decay time required after the measurement of high intensities.
                                   •  Automatic switching between SEM and Faraday with delay times <1ms.
                                   •  Wide crossover ranges (>2 orders of magnitude) between different detector modes allow accurate, automated cross-
                                      calibration.
                                   •  Dynamic range from 0.2cps (SEM) to >1 x 1012cps (Faraday).
                                ‹ View less
                             https://www.thermofisher.com/order/catalog/product/IQLAAEGAAMFABWMAFC                                                                                                                                                                13.03.2017
                     ELEMENT™ Series ICP-MS                                                                                                                                           Page 2 of 2
                        Documents
                        Product literature                                                                   Scientific posters
                            Application Note: Analysis of Non-Conductive Solid Samples by Laser Ablation         A New GC Interface for Sector Field ICP-MS
                        Interfaced with Extended Dynamic Range HR-ICP-MS                                         Expanding the Detectable Nanoparticle Size Range by High Resolution ICP-MS
                            Application Note: Analysis of Semiconductor Grade Mineral Acids by Sector            U-Pb Isotope Ratio Analysis of Zircons by Laser Ablation Coupled to Single 
                        Field ICP-MS                                                                         Collector Sector Field ICP-MS
                            Application Note: Applications of a High Performance Ion Detection System to 
                        the Analysis of Geological Samples by Sector Field ICP-MS
                            Application Note: Determination of Ultratrace Elements in Liquid Crystal by High 
                        Resolution ICP-MS
                            Application Note: Determination of Ultratrace Elements in Semiconductor Grade 
                        TMAH Developer by High Resolution ICP-MS
                            Application Note: ELEMENT XR: Extended Dynamic Range High Resolution ICP-
                        MS
                            Application Note: Enhancing Laser Ablation ICP-MS Using Sector Field 
                        Technology
                            Application Note: Enhancing the Performance of Single Collector Sector Field 
                        ICP-MS for Isotope Ratio Determinations
                            Application Note: Fast Scanning Sector Field ICP-MS with Laser Ablation for the 
                        Multi-Element Analysis of Elephant Tusk
                            Application Note: Geochemical Applications using Sector-Field High Resolution 
                        ICP-MS
                            Application Note: High Precision Determination of Sr/Ca and Mg/Ca Elemental 
                        Ratios in Massive Coral Skeletons
                            Application Note: High Precision Measurement of Magnesium to Calcium and 
                        Strontium to Calcium Elemental Ratios
                        Show more
                        Certificates
                        Search for Certificates of Analysis (COA) and Certificates of Conformance (COC) by lot number.
                        Lot number: 
                                                                      Search
                        Search unsuccessful? Request a certificate
                     https://www.thermofisher.com/order/catalog/product/IQLAAEGAAMFABWMAFC                                                                                            13.03.2017
The words contained in this file might help you see if this file matches what you are looking for:

...Element series icp ms page of spectroscopy elemental analysis instruments equipment other thermo scientific related applications industrial mass spectrometry choose from two high performance double focusing magnetic sector field that are optimized for ease use stability and productivity the features powerful techniques solve specific problems combined with excellent sensitivity signal to noise ratio xr extends linear dynamic range by an additional three orders magnitude using a faraday detector dual mode sem contact us support catalog number product size description price nok iqlaaegaamfabwmafc request quote full specifications iqlaaegaamfabwmafb is most technique quantification trace elements severe limitation polyatomic interference signals resolution gold standard elimination these interferences enabling accurate reliable quantitative multi analyses at levels even minimal sample preparation speed handle transient including hplc gc laser ablation free measurement across periodic tabl...

no reviews yet