jagomart
digital resources
picture1_Oil Pdf 178095 | Automatic Crude Oil Salt Content Analyzer Lcos A10


 168x       Filetype PDF       File size 0.26 MB       Source: www.labtron.com


File: Oil Pdf 178095 | Automatic Crude Oil Salt Content Analyzer Lcos A10
automatic crude oil salt content automatic crude oil salt content analyzer lcos a10 analyzer lcos a10 www labtron com info labtron com automatic crude oil salt content analyzer lcos a10 ...

icon picture PDF Filetype PDF | Posted on 29 Jan 2023 | 2 years ago
Partial capture of text on file.
    Automatic Crude Oil Salt Content 
    Automatic Crude Oil Salt Content 
            Analyzer LCOS-A10
            Analyzer LCOS-A10
        www.labtron.com      |      info@labtron.com
                                                                                                                    Automatic Crude Oil Salt Content 
                                                                                                                                    Analyzer LCOS-A10
         Automa�c Crude Oil Salt Content Analyzer LCOS-A10 is a computer-controlled automa�c crude oil 
         salt content analyzer designed as per ASTM D3230 specifica�ons, comprised with electric hea�ng 
         tube,  offers  automa�c  determina�on  of  �tra�on  end  point  through  poten�ometric  �tra�on 
         method.  Equipped  with  standard  �tra�on  extrac�on  device,  this  analyzer  offers  memory 
         pre-�tra�on, preset end-point �tra�on, blank �tra�on, manual �tra�on and other modes, in order 
         to  meet  different  experimental  requirements.  Integrated  design  with  mouse  and  keyboard 
         opera�on, this automa�c crude oil salt content analyzer instantly displays poten�al curve (E-V), first 
         deriva�ve  curve  (E/V),  electrode  poten�al  (E),  �tra�on  volume  (V),  �tra�on  results,  etc. 
         Incorporated with PID temperature control, digital display and adjustable voltage hea�ng, it has 
         automa�c cleaning, automa�c replenishment and automa�c liquid addi�on of fixed value, ensures 
         easy and flexible opera�on with accuracy.
         Features :
           Computer-controlled automa�c crude oil salt content analyzer designed as per ASTM D3230 
              specifica�ons
          Electric hea�ng tube with adjustable voltage hea�ng
          Automa�c determina�on of �tra�on end point through poten�ometric �tra�on method
          Equipped with standard �tra�on extrac�on device
          Offers memory pre-�tra�on, preset end-point �tra�on, blank �tra�on, manual �tra�on
          Customized modes, in order to meet different experimental requirements
          Integrated design with mouse and keyboard opera�on
          Instantly  displays  poten�al  curve  (E-V),  first  deriva�ve  curve  (E/V),  electrode  poten�al  (E), 
              �tra�on volume (V), �tra�on results, etc.
          PID temperature control with digital display, easy to operate
          Automa�c cleaning, automa�c replenishment and automa�c liquid addi�on of fixed value
          Highly-efficient, accurate and easy to use with flexible opera�on
         Applica�on :
         Automa�c Crude Oil Salt Content Analyzer is used for determina�on of chloride (salt) content in 
         crude oils across refineries, pipelines, terminals, laboratories, inspec�on companies, oil pla�orms 
         etc.
                                                                 Automatic Crude Oil Salt Content 
                                                                         Analyzer LCOS-A10
     Specifica�ons
      Model                                   LCOS-A10
      Measuring range                         Temperature: -5.0°C to 105.0°C
                                              pH: 0.00 to 14.00
                                              mV: -1800 to 1800
      Resolu�on                               Temperature: 0.1°C
                                              pH: 0.01
                                              mV: 0.1
      Basic error                             Temperature: ±0.3°C ± 1 word
                                              pH: ±0.01 ± 1 word
                                              mV: ±0.03% FS
      Control temperature                     60°C ±1°C
      Bure�e capacity tolerance               10 ml bure�e: ± 0.025 ml
                                              20 ml bure�e: ±0.035 ml
      Bure�e resolu�on                        10 ml bure�e: 1/10000 
                                              20 ml bure�e: 2/10000
      Bure�e infusion speed                   50 ± 10 s (when bure�e is full)
      Titra�on analysis repeatability         0.2%
      Titra�on control sensi�vity             ± 2 mV
      Stability                               (± 0.3 mV ± 1 word)/3 h
      Temperature controller                  PID
      Display                                 Digital
      Hea�ng tube                             Electric
      Power supply                            AC 220 ± 22 V, 50 ± 1 Hz
      Host apparatus dimension (W×D×H)        460×480×580 mm
      Host apparatus weight                   36 kg
      Titra�on device dimension (W×D×H)       460×700×1140 mm
      Titra�on device weight                  55 kg
The words contained in this file might help you see if this file matches what you are looking for:

...Automatic crude oil salt content analyzer lcos a www labtron com info automac is computer controlled designed as per astm d specicaons comprised with electric heang tube oers determinaon of traon end point through potenometric method equipped standard extracon device this memory pre preset blank manual and other modes in order to meet dierent experimental requirements integrated design mouse keyboard operaon instantly displays potenal curve e v rst derivave electrode volume results etc incorporated pid temperature control digital display adjustable voltage it has cleaning replenishment liquid addion xed value ensures easy exible accuracy features customized operate highly ecient accurate use applicaon used for chloride oils across reneries pipelines terminals laboratories inspecon companies plaorms model measuring range c ph mv resoluon basic error word fs buree capacity tolerance ml infusion speed s when full titraon analysis repeatability sensivity stability h controller power supply...

no reviews yet